Warenkorb
Kostenloser Versand
Unsere Operationen sind klimaneutral

Guidance Note 5: Protection Against Electric Shock The Institution of Engineering and Technology

Guidance Note 5: Protection Against Electric Shock von The Institution of Engineering and Technology

Guidance Note 5: Protection Against Electric Shock The Institution of Engineering and Technology


€17.99
Zustand - Sehr Gut
Nur noch 1

Zusammenfassung

Guidance Note 5: Protection Against Electric Shock provides a core element of safety for specifiers, designers, contractors and inspectors. It includes clear guidance on how to apply the safety requirements of BS 7671 concerning electric shock and has been fully updated to BS 7671:2018.

Guidance Note 5: Protection Against Electric Shock Zusammenfassung

Guidance Note 5: Protection Against Electric Shock The Institution of Engineering and Technology

Guidance Note 5: Protection Against Electric Shock provides a core element of safety for specifiers, designers, contractors and inspectors. It includes clear guidance on how to apply the safety requirements of BS 7671 concerning electric shock and has been fully updated to BS 7671:2018.

The 18th Edition of the IET Wiring Regulations published in July 2018 and came into effect in January 2019. Changes from the previous edition include requirements concerning Surge Protection Devices, Arc Fault Detection Devices and the installation of electric vehicle charging equipment as well as many other areas.

Inhaltsverzeichnis

  • Chapter 1: Statutory Regulations and The Wiring Regulations
  • Chapter 2: Electric shock and protective measures
  • Chapter 3: Provisions for basic protection
  • Chapter 4: Automatic disconnection of supply
  • Chapter 5: Double or reinforced insulation
  • Chapter 6: Electrical separation
  • Chapter 7: Extra-low voltage provided by SELV or PELV
  • Chapter 8: Additional protection
  • Chapter 9: Obstacles and placing out of reach
  • Chapter 10: Protective measures for application only where the installation is controlled or under the supervision of skilled or instructed persons
  • Chapter 11: Earthing
  • Chapter 12: Circuit protective conductors
  • Chapter 13: Protective equipotential bonding
  • Chapter 14: Protective multiple earthing
  • Chapter 15: Special installations or locations
  • Chapter 16: Cables installed in walls, floors, ceilings and partitions
  • Appendix A: Maximum permissible measured earth fault loop impedance
  • Appendix B: Resistance of copper and aluminium conductors

Zusätzliche Informationen

GOR011467406
9781785614583
1785614584
Guidance Note 5: Protection Against Electric Shock The Institution of Engineering and Technology
Gebraucht - Sehr Gut
Broschiert
Institution of Engineering and Technology
20181210
136
N/A
Die Abbildung des Buches dient nur Illustrationszwecken, die tatsächliche Bindung, das Cover und die Auflage können sich davon unterscheiden.
Dies ist ein gebrauchtes Buch. Es wurde schon einmal gelesen und weist von der früheren Nutzung Gebrauchsspuren auf. Wir gehen davon aus, dass es im Großen und Ganzen in einem sehr guten Zustand ist. Sollten Sie jedoch nicht vollständig zufrieden sein, setzen Sie sich bitte mit uns in Verbindung.