Guidance Note 1: Selection & Erection contains clear guidance on how to apply the relevant sections of BS 7671. A fundamental guide for specifiers, installers and those testing installations, the expected updates in Amendment 3 greatly impact on day-to-day tasks.

Guidance Note 1: Selection & Erection Zusammenfassung

Guidance Note 1: Selection & Erection The Institution of Engineering and Technology

Guidance Note 1: Selection & Erection contains clear guidance on how to apply the relevant sections of BS 7671. A fundamental guide for specifiers, installers and those testing installations, the expected updates in Amendment 3 greatly impact on day-to-day tasks.

The main changes to BS 7671 that impact Guidance Note 1 include information on:

  • consumer units (to come into effect January 2016);
  • wiring in escape routes;
  • changes to earth fault loop impedances for all protective devices;
  • changes to definitions throughout the Regulations.

Please note, sections previously in Guidance Note 1 on Outdoor Lighting and ELV Lighting can now be found in Guidance Note 7 (5th Edition).

Amendment 3 published on 5 January 2015 and comes into effect on 1 July 2015. All new installations from this point must comply with Amendment 3 to BS 7671:2008.

Inhaltsverzeichnis

  • Chapter 1: General requirements
  • Chapter 2: Selection and erection of equipment
  • Chapter 3: Protection against overcurrent, electric shock and overvoltage
  • Chapter 4: External influences
  • Chapter 5: Installation of cables
  • Chapter 6: Sizing of cables
  • Chapter 7: Other influences
  • Chapter 8: Installation of equipment
  • Appendix A: Cable capacities of conduit and trunking
  • Appendix B: Degrees of protection provided by enclosures
  • Appendix C: Standard circuit arrangements and the provision of socket-outlets
  • Appendix D: Limitation of earth fault loop impedance for compliance with Regulation 543.1.1
  • Appendix E: Resistance and impedance of copper and aluminium conductors under fault conditions
  • Appendix F: Selection and erection of wiring systems
  • Appendix G: Notes on methods of support for cables, conductors and wiring systems
  • Appendix H: Maximum demand and diversity
  • Appendix I: Permitted protective conductor currents
  • Appendix J: Standard symbols, units and graphical symbols for general electrical purposes
  • Appendix K: Addresses of associated bodies and industry contacts

Zusätzliche Informationen

GOR009179360
9781849198691
1849198691
Guidance Note 1: Selection & Erection The Institution of Engineering and Technology
Gebraucht - Sehr Gut
Broschiert
Institution of Engineering and Technology
20150116
228
N/A
Die Abbildung des Buches dient nur Illustrationszwecken, die tatsächliche Bindung, das Cover und die Auflage können sich davon unterscheiden.
Dies ist ein gebrauchtes Buch. Es wurde schon einmal gelesen und weist von der früheren Nutzung Gebrauchsspuren auf. Wir gehen davon aus, dass es im Großen und Ganzen in einem sehr guten Zustand ist. Sollten Sie jedoch nicht vollständig zufrieden sein, setzen Sie sich bitte mit uns in Verbindung.